Audi 80/Avant (B4)

since 1991-1995 of release

Repair and car operation



Audi 80/Avant
+ Technical specification
+ Engines
+ System of production of the fulfilled gases
+ cooling System
+ Fuel tank and fuel pump
+ Air filter and airintaking channels
- Injection system
   + System of injection of Mono-Motronic
   + System of injection of Digifant
   + System of injection of KE-III-Jetronic
   - Systems of injection of MPI and MPFI
      Operating procedure
      Lambda regulation
      Malfunctions and independent diagnostics
      Independent repair
      Visual check
      Check of separate elements
      Removal of elements
      Hummock drive of "gas"
      Check of a mode of idling and analysis of exhaust gases
      List of malfunctions
+ Coupling
+ Transmission and transmission
+ Suspension bracket and steering
+ Brake system
+ Anti-blocking system of brakes
+ Wheels and tires
+ Body electrosystem
+ ignition System
+ Lighting
+ Signalling devices
+ Devices and auxiliary devices
+ Heating and ventilation
+ body Elements
+ Search of malfunctions
+ Specifications




Visual check

 PERFORMANCE ORDER

  1. For a start check air lines on tightness! All hoses – from a thick sleeve of an air inlet to thin vacuum hoses should be checked.
  2. Whether
  3. as it should be sealing laying of vpryskny nozzles, and also flange laying of inlet channels?
  4. Not tight places open access to unrecorded air, that is air which is not considered by system and consequently essentially disturbs mix preparation. The mix nekontrolirovanno is impoverished. A consequence of it are malfunctions in operation of the engine, being shown first of all in rough idling.
  5. To warm up the engine to working temperature, then to leave to work at single turns, to open a cowl, to separate plug connection to a lambda probe.
  6. To sprinkle from a spray containing starting fuel (for example «Startpilot») sealing flange laying of inlet channels and other details inspiring suspicion.
  7. If frequency of rotation changes when spraying a certain place, means, there was a leakage.
  8. Whether
  9. it is possible to distinguish a leakage of toplivoprovodny hoses?
  10. Whether tips of wires
  11. were repeatedly disconnected and are again connected? Corrosion or inept actions can lead to insufficient contact.